Ceramic Chip Capacitor Acoustic Microscope Image and Cross-Section
Application Note 2083
Voids and Delaminations
Sample & Method

A set of five multilayer ceramic chip capacitors were imaged on the C-SAM instrument using a 50 MHz, ½” focal length transducer.  The echoes were gated to include the bulk, active area of the capacitor between the top and back surfaces.  Correlative Acoustically Guided – Destructive Physical Analysis (AG-DPA) was also performed on Part #5 to further characterize the presence of defects.

Result

Bright white areas within the boundary of each capacitor in the image indicate voids and delaminations within the capacitors.  Large termination-to-termination delaminations are evident in Parts 1, 2 and 5.  Voids are evident in all
of the parts.

The full view (right) AG-DPA image shows the visual evidence of a portion of the large termination-to-termination delamination. 